    This unit employs a compression refrigeration system and a highly intelligent temperature controller, offering advantages such as high temperature control accuracy, rapid cooling speed, an advanced overall design, an elegant appearance, and exceptional durability. Additionally, this unit can also be used for constant-temperature testing of experimental samples in fields such as petroleum, chemical engineering, pharmaceuticals, and biotechnology.

    II. Technical Parameters:

    1. Power supply: 220V ±10V, 50Hz

    2. Heating power: 4000W

    3. Cooling capacity: 800W

    4. Temperature control accuracy: ±1℃

    5. Temperature control range: 5-80℃

    6. Inner liner dimensions: 800*600*500 (mm)

    III. Instructions for Use:

    1. The equipment should be placed indoors at a room temperature between 10°C and 30°C with relative humidity no higher than 80%. The back of the equipment should be kept at least 30 centimeters away from the wall, and the room should have good ventilation.

    2. After connecting the power supply (the power supply should be equipped with an air switch featuring leakage protection), fill the water tank with water. The water level must not fall below the bottom grate.

    3. The selected power supply must have a wattage equal to or greater than the instrument’s total power consumption, and the power supply must also be equipped with a reliable grounding system.

    4. Set the desired test temperature, then turn on the heating, cooling, and water pump switches! (At the start of heating or cooling, the temperature may temporarily exceed the actual set temperature; however, the instrument will automatically adjust internally to gradually return to the set temperature.)

    5. After use, turn off the power, unplug the power cord, and drain all water from the device. Wipe it clean and set it aside for future use.

    IV. Instrument Operation:

    1. When the required temperature is higher than the ambient temperature, proceed as follows:

    A Turn on the power switch

    B Turn on the loop switch

    Press and hold the SET key for 0.5 seconds, and the meter will enter the master control setting mode. Set the desired temperature, then press the SET key again for 0.5 seconds to return the meter to its normal control state.

    V. Precautions

    1. When installing the equipment, please check whether the connections are correct.

    2. To ensure safety, please connect the ground wire properly.

    3. If the device is not functioning properly, please contact the manufacturer or the distributor—do not disassemble it yourself.

    4. When the room temperature drops below 0℃, be sure to drain all the water from the water tank and the circulating pump to prevent freezing and cracking.

Company Profile

Hebei Yinfeng Experimental Instrument Co., Ltd. is a high-tech enterprise dedicated to the research and development, production, and sales of experimental instruments. The company is headquartered in Hebei Province, relying on the strong industrial foundation and technological innovation resources in the Beijing Tianjin Hebei region. It is committed to providing high-precision and high reliability testing equipment and solutions for material testing, engineering quality control, scientific research experiments and other fields.

Plant
Factory environment
Workshop
Workshop environment

Customized Delivery Process

We provide customers with full-process services ranging from pre-sale consultation, customized solution design, equipment installation and commissioning to after-sale technical support.

Online Communication

Provide Custom Drawings

Merchant Quotation

Sign A Contract

Processing And Production

Packaging And Distribution

Confirm Receipt Of Goods

Successful Transaction

  • DXDL-SY Type Constant-Temperature Water Bath for Wires and Cables
DXDL-SY Type Constant-Temperature Water Bath for Wires and Cables
+

DXDL-SY Type Constant-Temperature Water Bath for Wires and Cables

DXDL-SY Type Wire and Cable Constant-Temperature Water Bath Instruction Manual I. Scope of Use: This unit employs a compressor-based refrigeration system and a highly intelligent temperature controller, offering advantages such as high temperature control accuracy, rapid cooling speed, advanced overall design, elegant appearance, and durability. Additionally, this unit can also be used for constant-temperature testing of experimental samples in fields such as petroleum, chemical industry, pharmaceuticals, and biology. II. Technical Parameters: 1. Power Supply: 220V ±10V, 50Hz 2. Heating Power: 4000W 3. Cooling Power: 800W 4. Temperature Control Accuracy: ±1℃ 5. Temperature Control Range: 5–80℃ 6. Inner Tank Dimensions: 800×600×500 (mm) III. Instructions for Use: 1. The equipment should be placed indoors at a room temperature between 10℃ and 30℃ with relative humidity no higher than 80%. The back of the equipment should be kept at least 30 centimeters away from walls, and the room should have good ventilation. 2. After connecting the power supply (the power supply must be equipped with an air switch with leakage protection), fill the water tank with water. The water level must not fall below the bottom grate. 3. The selected power supply must have a wattage equal to or greater than the total power consumption of the instrument; additionally, the power supply must have a reliable grounding device. 4. Set the desired test temperature, then turn on the heating, cooling, and pump switches! (At the beginning of heating or cooling, the temperature may temporarily exceed the set value, but the instrument will automatically adjust internally and gradually return to the set temperature.) 5. After use, turn off the power, unplug the power cord, drain all the water from the equipment, and wipe it clean for future use. IV. Instrument Operation: 1. When the desired temperature is higher than the ambient temperature, proceed as follows: A. Turn on the power switch. B. Turn on the circulation switch. C. Press and hold the SET key for 0.5 seconds to enter the main control setting mode. Set the desired temperature, then press the SET key again for 0.5 seconds to return to the normal control state. V. Precautions: 1. Before installing the equipment, please check that all connections are correct. 2. To ensure safety, make sure the grounding wire is properly connected. 3. If the equipment malfunctions, contact the manufacturer or distributor—do not disassemble it yourself. 4. When the room temperature drops below 0℃, be sure to drain all the water from the water tank and the circulating pump to prevent freezing and cracking.

If you need customized products,  Contact US !

Share to

Request a Quote

We will contact you within one working day. Please pay attention to your email.

Related Products

Content update in progress

Request Quote

We will contact you within one working day. Please pay attention to your email.

SUBMIT