• Ca-5 Free Calcium Oxide Analyzer
  • Ca-5 Free Calcium Oxide Analyzer
  • Ca-5 Free Calcium Oxide Analyzer
  • Ca-5 Free Calcium Oxide Analyzer
Ca-5 Free Calcium Oxide Analyzer
Ca-5 Free Calcium Oxide Analyzer
Ca-5 Free Calcium Oxide Analyzer
Ca-5 Free Calcium Oxide Analyzer
+
  • Product Describe
  • Operating Instructions

    This instrument is a controller that integrates both automatic and manual operation; the operation panel is shown in the figure below.

    Figure 1

    The specific key operations are as follows:

    1. [Heating] Button: Press this button to turn on the heating light; adjusting the potentiometer will activate the heating function. If heating is not required, press the button again to turn off the heating light and stop heating.

    2. [Stir] Button: Press this button to turn on the stir light and adjust the potentiometer to rotate the motor, allowing the stirring bar to mix the contents. If stirring is not required, press the button again to turn off the stir light and stop stirring.

    3. [Cooling] Button: Press this button to turn on the cooling light and start the air pump. If cooling is not required, press the button again to turn off the cooling function and stop the air pump from operating.

    4 [ +10 ] Each time this key is pressed, the tens digit increases by one. (This key is ineffective when the device is in operation.)

    5 [ +1 ] Each time this key is pressed, the ones digit increases by one (this key has no effect when the device is in operation).

    6. [Start/Stop] Key: The first time you press this key, the start indicator light turns on and simultaneously activates the stirring, heating, and cooling outputs. The [Heating] key controls the heating output, the [Stirring] key controls the stirring output, and the [Cooling] key controls the cooling output. The clock begins counting down; when the countdown reaches zero, the start indicator light turns off. All outputs are disabled, and the alarm continues to sound. Pressing the key a second time will stop the alarm as well. If you press the key a second time while the system is running, all outputs are disabled, timing stops, and operation ceases.

    Overview

    This instrument is a complementary device for the rapid determination of free calcium oxide using ethylene glycol. It features advantages such as fast heating, uniform stirring, stable data, and simple operation.

    Technical Indicators

    Power supply: 220V ±10%, 50Hz

    Motor: Stepless speed regulation

    Power: 300W

    Time: 1–99 minutes

    Water pump: AC 220V 50Hz

    Instrument Operation

    This instrument offers both automatic and manual operation modes and requires no complicated installation; it is easy to operate and convenient to use. The user manual is as follows:

    1. When using this instrument, you must place it on a level surface.

    2. Before placing the Erlenmeyer flask, first push the movable rod upward with your hand, then carefully lower your hand as you position the flask on the hot plate; the condenser should be securely connected to the Erlenmeyer flask.

    3. The water in the bucket should reach about three-quarters of its capacity, approximately 1500 ml (Place the bucket inside the instrument, add water to the bucket: first use a screwdriver to loosen the screws, open the upper rear cover of the instrument, fill the bucket with water, then securely reattach the rear cover).

    4. After powering on, if you need to preheat, stir, or cool first, simply press the [Heat], [Stir], or [Cool] button. To switch to automatic mode, first set the desired runtime, then press the [Start/Stop] button.

    Precautions for Use

    1: When using the instrument, a good grounding device must be in place.

    *2: The instrument must not be heated under no-load conditions for extended periods.

    3: When the instrument is not used for an extended period, the power plug should be removed.

    Packing List

    1: 2 250 mL Erlenmeyer flasks

    2: 2 magnetic stir bars

    3: Free Calcium Host 1 unit

    4: 1 power cord

    5: 2 condensation tubes

    6e138d4096a330ad3fd7204dae5cf81

Company Profile

Hebei Yinfeng Experimental Instrument Co., Ltd. is a high-tech enterprise dedicated to the research and development, production, and sales of experimental instruments. The company is headquartered in Hebei Province, relying on the strong industrial foundation and technological innovation resources in the Beijing Tianjin Hebei region. It is committed to providing high-precision and high reliability testing equipment and solutions for material testing, engineering quality control, scientific research experiments and other fields.

Plant
Factory environment
Workshop
Workshop environment

Customized Delivery Process

We provide customers with full-process services ranging from pre-sale consultation, customized solution design, equipment installation and commissioning to after-sale technical support.

Online Communication

Provide Custom Drawings

Merchant Quotation

Sign A Contract

Processing And Production

Packaging And Distribution

Confirm Receipt Of Goods

Successful Transaction

Next:

  • Ca-5 Free Calcium Oxide Analyzer
  • Ca-5 Free Calcium Oxide Analyzer
  • Ca-5 Free Calcium Oxide Analyzer
  • Ca-5 Free Calcium Oxide Analyzer
Ca-5 Free Calcium Oxide Analyzer
Ca-5 Free Calcium Oxide Analyzer
Ca-5 Free Calcium Oxide Analyzer
Ca-5 Free Calcium Oxide Analyzer
+

Ca-5 Free Calcium Oxide Analyzer

This instrument is a complementary device for the rapid determination of free calcium oxide using ethylene glycol. It features advantages such as fast heating, uniform stirring, stable data, and simple operation.

If you need customized products,  Contact US !

Share to

Request a Quote

We will contact you within one working day. Please pay attention to your email.

Related Products

Content update in progress

Request Quote

We will contact you within one working day. Please pay attention to your email.

SUBMIT