- Product Describe
-
Capacity 115L Temperature Range 0℃~-40℃ Temperature Control Accuracy ±2℃ Power Supply AC220V 50HZ Ambient Temperature 0~23℃ Compressor Domestic Internal Dimensions 470*425*490mm External Dimensions 590*600*850mm Purpose and Features
This equipment is suitable for low-temperature quick-freezing tests of various products, such as chemicals, physics, pharmaceuticals, instruments, meters, electrical appliances, marine biology, etc. It is used for low-temperature storage of vaccines and serums, microbiological research and cultivation, drug testing and storage, low-temperature testing of building materials, etc. The instrument consists of a branded compressor, condenser, filter, capillary tube, evaporator constant temperature bath, digital display instrument, and digital temperature control system. The machine cools quickly, operates quietly, and is reliable and convenient to use.
Technical Parameter Box
Instrument Capacity:
Vertical: 30L, 40L, 60L, 80L, 200L
Horizontal: 30L, 115L, 160L, 190L, 230LLowest Temperature: -25℃, -40℃, -50℃, -60℃, -80℃, -100℃
Temperature Control Accuracy (Uniformity): ±2℃ (also available with high precision ±0.5℃)
Compressor: Domestic compressor (also available with Brazilian Embraco imported compressor)
Power Supply: AC220V, 50Hz
Constant Humidity: (Adjustable range 20-95%)
Ambient Temperature: 0-23℃.
Structural Features
This instrument features a top-opening door, thickened insulation layer for good low-temperature retention and convenient experiments. The constant temperature bath uses a highly corrosion-resistant alloy plate, with high-quality steel plate on the outside and polyurethane foam insulation material in the middle.
Precautions
1. The instrument must not be stored or used in environments with humidity or corrosive gases.
For the first use (or after long periods of inactivity), the machine must operate for 2 hours before testing to avoid inaccurate initial readings.
2. In case of power outage or interruption, immediately turn off the power switch. If restarting is needed, wait at least 30 minutes before turning on the machine again to avoid compressor damage from rapid startup.
3. This instrument is suitable for laboratory testing.
4. It is strictly forbidden to run the machine for long periods when not in use.
5. During transportation, the tilt angle must not exceed 45° to avoid compressor or system damage. When in use, remove all packaging. Leave more than 50cm space behind the freezer and more than 15cm on both sides from the wall. The freezer should be placed in a ventilated and dry place, avoid direct sunlight, and keep away from pools, heat sources, magnetic fields, and various volatile or corrosive substances.
6. A dedicated socket must be used. The current capacity of the socket and wiring should be no less than 10A, and the socket must be reliably grounded.
7. The power supply is single-phase AC 50Hz, voltage 220-242V. If voltage is unstable, install a voltage stabilizer with at least 5 times the input power. Use a stabilizer to regulate: 220V 50Hz 15A. The instrument must be grounded.
Freezing Instructions
1. When placing samples, leave some space between samples and between samples and the inner wall of the freezer to ensure air circulation and uniform cooling.
2. For samples with high humidity or prone to moisture loss, wrap them tightly in sealed food bags or cling film to prevent moisture from escaping and causing frost inside the chamber, which affects cooling.
3. It is strictly forbidden to store volatile or flammable gases and liquids in the freezer, such as strong alkalis, strong acids, gasoline, alcohol, etc.
4. Do not overload the freezer with samples at one time, as this will cause the compressor to run continuously for a long time and slow temperature decrease, failing to meet requirements.
5. After work, cut off the power, remove frozen samples, open the freezer door to allow natural warming, let frost melt, drain water, and wipe dry with a soft cloth.
Usage Instructions
1. Carefully read the user manual before using the quick freezer.
2. Pre-start check: A) The quick freezer must have an independent power socket and reliable grounding. Voltage fluctuation range allowed is 220-240V, frequency 49-51Hz. B) Before connecting external power, ensure the panel switch is off.
3. Start-up: Plug in the power, turn the panel power switch on. The display will show the chamber temperature. After the computer temperature controller's delay time, the compressor starts running.
4. Operation: Once the temperature reaches the set value, quickly and evenly place the stored items inside the chamber.
5. Shutdown: After use, first turn off the panel power switch (display off), then cut off external power.
Maintenance and Care
1. The freezer should be cleaned after each test during use. When cleaning, cut off the power, remove items, and wipe off moisture and dirt.
2. Do not use boiling water, acidic agents, chemical diluents, etc.
3. After cleaning, wipe it dry.
4. When cleaning the door seal, please use mild soapy water and wipe carefully.
5. When cleaning the outer shell, water or a small amount of neutral detergent can be used. Be careful not to immerse the power cord or lower wiring in water to avoid moisture and electric leakage.
Common faults and troubleshooting methods
1. Indicator does not light up; no instrument display after turning on the switch. Check the power supply and plug.
2. Indicator light is on, but the compressor is not working properly, only a humming sound. If voltage is low, install a voltage stabilizer with at least 5 times input capacity.
3. The compressor starts but stops within one minute, then after a few minutes restarts repeatedly. Repair according to item 2.
4. Compressor works normally but cooling is slow: ① Frequent door openings or door not closed tightly. ② Too many items placed inside or improper placement. ③ Frost buildup in the freezer.
5. Excessive noise: ① Freezer is not placed on a stable surface. ② Loose fasteners on the freezer. ③ Contact between the refrigeration box and compressor.
The following phenomena are not faults, please do not worry.
1. When the quick-freezing box is working or shortly after stopping, the refrigerant circulates inside the pipes, producing a gurgling water sound.
2. The compressor surface temperature may reach 70℃ to 80℃ during operation.
3. When the compressor starts or stops, the switch components may produce slight clicking sounds.
4. During rainy and humid seasons, frost may form on the surface of the box; wipe it off with a dry cloth.
5. The inner side of the quick-freezing box lining is a stress relief area under ultra-low temperatures. Slight cracks may appear under alternating high and low temperatures, which is normal and does not affect use.
Maintenance Instructions
1. If abnormal phenomena or faults occur during use, please have a professional technician repair it (or under manufacturer guidance).
2. Our factory provides free spare parts for domestic compressors (custom machines) within one year from the date of shipment, and free one-year warranty for imported compressors (standard machines).
3. Warranty period: one year from delivery and acceptance, excluding fragile glass parts (no returns or exchanges for custom machines). During the warranty, logistics costs are paid by the sender (who ships pays), spare parts are provided free by the factory, with technical support. If the compressor is replaced, a service fee of 150 yuan is charged by the factory, and refrigerant is provided free. For glass-covered low-temperature boxes, a quilt should be placed on the cover for insulation.
Note: 1. After unpacking, remove the base and keep it ventilated.
2. Please keep the wooden crate packaging for maintenance use; otherwise, the user bears the cost.
3. It is strictly forbidden to operate continuously in environments above 35℃.
Digital temperature controller instructions:
Quickly press the “set” button three times consecutively to enter the setting mode: first, the lower limit setting value is displayed (negative F). Use the up or down keys to select the lower limit value, then press set to lock it. The upper limit value (positive F) is displayed next; use the up or down keys to select the upper limit value, then press set to lock it. The delay status Y is displayed—Y03 means a 3-minute delay before starting (must be set to Y03 to avoid compressor damage). Press set to lock the delay value. The JCC refrigeration mode is displayed (must be JCC). Press set to lock the refrigeration mode. The C-6 temperature calibration range is displayed (factory adjusted). Press set to lock. After waiting 16 seconds, all settings are saved and the actual internal temperature is displayed. (After setting, press the set button once more and wait 16 seconds before turning off, otherwise settings will not be saved).
Setting example: (1) -25 degrees — lower limit negative F25, upper limit positive F22, delay Y03, refrigeration JCC, calibration C-6. (Special note: The horizontal line between negative F and positive F flashes to indicate below zero; otherwise, positive L and negative L indicate above zero.) (2) -40 degrees — lower limit -40, upper limit -37, refrigeration, Y03, JCC, C-6.
(3) -50 degrees — lower limit -50, upper limit -47, delay Y03, ... Wiring instructions: 1 neutral line, 2 live line. Refrigeration output 1,3. 2 and 4 in series.
Special note on temperature calibration C-6:
If there is a discrepancy between the internal box temperature and the instrument display temperature, quickly press the SET button three times: (1) negative F appears, (2) press SET again to show positive F, (3) press SET again to show Y03, (4) press SET again to show JCC, (5) press SET again to show C-6 for internal sensor calibration (calibration range -6 to +6). After setting, press SET once more to confirm the value. Example: if the instrument shows -24 degrees but the box temperature is -25 degrees, change C-6 to C-1.
Company Profile
Hebei Yinfeng Experimental Instrument Co., Ltd. is a high-tech enterprise dedicated to the research and development, production, and sales of experimental instruments. The company is headquartered in Hebei Province, relying on the strong industrial foundation and technological innovation resources in the Beijing Tianjin Hebei region. It is committed to providing high-precision and high reliability testing equipment and solutions for material testing, engineering quality control, scientific research experiments and other fields.




Customized Delivery Process
We provide customers with full-process services ranging from pre-sale consultation, customized solution design, equipment installation and commissioning to after-sale technical support.
Online Communication
Provide Custom Drawings
Merchant Quotation
Sign A Contract
Processing And Production
Packaging And Distribution
Confirm Receipt Of Goods
Successful Transaction



Horizontal 115L Constant Temperature and Humidity Chamber
If you need customized products, Contact US !
Tag list
Request a Quote
We will contact you within one working day. Please pay attention to your email.
Related Products
Content update in progress