• Horizontal 160L Constant Temperature and Humidity Chamber
  • Horizontal 160L Constant Temperature and Humidity Chamber
  • Horizontal 160L Constant Temperature and Humidity Chamber
Horizontal 160L Constant Temperature and Humidity Chamber
Horizontal 160L Constant Temperature and Humidity Chamber
Horizontal 160L Constant Temperature and Humidity Chamber
+
  • Product Describe
  • Capacity 160L
    Temperature Range 0℃~-40℃
    Temperature Control Accuracy ±2℃
    Power Supply AC220V 50HZ
    Ambient Temperature 0~23℃
    Compressor Imported Embraco from Brazil
    Internal Dimensions 735*425*470mm
    External Dimensions 870*600*830mm

     

    Uses and Features

    This equipment is suitable for low-temperature quick-freezing tests of various products, such as chemicals, physics, pharmaceuticals, instruments, meters, electrical appliances, marine biology, etc. It is used for low-temperature storage of vaccines and serums, microbiological research and cultivation, drug testing and storage, low-temperature testing of building materials, etc. The instrument consists of a branded compressor, condenser, filter, capillary tube, evaporator constant temperature bath, digital display instrument, and digital temperature control system. The machine cools quickly, operates quietly, and is reliable and convenient to use.

    Technical Parameter Box

    Instrument Capacity:

    Vertical: 30L, 40L, 60L, 80L, 200L
    Horizontal: 30L, 115L, 160L, 190L, 230L

    Lowest Temperature: -25℃, -40℃, -50℃, -60℃, -80℃, -100℃

    Temperature Control Accuracy (Uniformity): ±2℃ (also available with high precision ±0.5℃)

    Compressor: Domestic compressor (also available with imported Brazilian Embraco compressor)

    Power Supply: AC220V, 50Hz

    Constant Humidity: (Adjustable range 20-95%)

    Ambient Temperature: 0-23℃.

    Structural Features

    This instrument features a top-opening door, thickened insulation layer for good low-temperature retention, convenient experiments, a corrosion-resistant alloy plate for the constant temperature bath, high-quality steel plate exterior, and polyurethane insulation material in the middle.

    Precautions

    1. The instrument must not be stored or used in environments with humidity or corrosive gases.

    For the first use (or after long periods of inactivity), the machine must operate for 2 hours before testing to avoid inaccurate initial readings.

    2. In case of power outage or interruption, immediately turn off the power switch. If restarting is needed, wait at least 30 minutes before turning it on again to avoid compressor damage from rapid startup.

    3. This instrument is suitable for laboratory testing.

    4. It is strictly forbidden to run the machine for long periods when not in use.

    5. During transportation, the tilt angle must not exceed 45° to avoid compressor or system damage. When in use, remove all packaging. Leave more than 50cm space behind the freezer and more than 15cm on both sides. Place the freezer in a ventilated, dry place, avoid direct sunlight, and keep away from water, heat sources, magnetic fields, and volatile or corrosive substances.

    6. Must use an independent socket. The current capacity of the socket and wires should be no less than 10A, and the socket must be reliably grounded.

    7. Use AC single-phase 50Hz power supply, voltage 220-242V. If voltage is unstable, install a voltage stabilizer with at least 5 times the input power. Use a stabilizer set to 220V 50Hz 15A. The instrument must be grounded.

    Freezing Instructions

    1. When placing samples, leave some space between samples and between samples and the freezer inner wall to ensure air circulation and uniform cooling.

    2. For samples with high humidity or prone to moisture loss, wrap them tightly in sealed food bags or cling film to prevent moisture from escaping and causing frost inside the chamber, which affects cooling.

    3. It is strictly forbidden to store volatile or flammable gases and liquids in the freezer, such as strong alkalis, strong acids, gasoline, alcohol, etc.

    4. Do not overload the freezer with samples at one time, as this will cause the compressor to run continuously and the internal temperature to drop slowly, failing to meet requirements.

    5. After work, cut off the power, remove frozen samples, open the freezer door to allow natural warming, let frost melt, drain water, and wipe dry with a soft cloth.

    Usage Instructions

    1. Carefully read the user manual before using the quick freezer.

    2. Pre-start check: A) The quick freezer must have an independent power socket and reliable grounding. Voltage fluctuation range allowed is 220-240V, frequency 49-51Hz. B) Before connecting external power, ensure the panel switch is off.

    3. Start-up: Plug in the power, turn the panel power switch on. The display will show the chamber temperature. After the computer temperature controller's delay time, the compressor starts running.

    4. Operation: Once the temperature reaches the set value, quickly and evenly place the stored items inside the chamber.

    5. Shutdown: After use, first turn off the panel power switch (display off), then cut off external power.

    Maintenance and Care

    1. The freezer should be cleaned after each test during use. When cleaning, cut off the power, remove items, and wipe off any dirt and moisture.

    2. Do not use boiling water, acidic agents, chemical diluents, etc.

    3. After cleaning, wipe it dry.

    4. When cleaning the door seal, please use mild soapy water and wipe carefully.

    5. When cleaning the exterior, you can use water or a small amount of neutral detergent. Be careful not to let the power cord or lower wiring get wet to avoid moisture and electric leakage.

    Common faults and troubleshooting methods

    1. Indicator does not light up; no display on the meter after turning on the switch. Check the power supply and plug.

    2. Indicator light is on, but the compressor is not working properly, only humming sound. If voltage is low, install a voltage stabilizer with more than 5 times input.

    3. The compressor starts but stops within 1 minute, then after a few minutes restarts repeatedly. Repair according to item 2.

    4. Compressor is normal but cooling is slow: (1) Frequent door openings or door not closed tightly. (2) Too many items placed improperly. (3) Freezer is frosted.

    5. Excessive noise: (1) Freezer is not placed stably. (2) Freezer fixtures are loose. (3) Freezer and compressor are in contact.

    The following phenomena are not faults, please do not worry.

    1. When the freezer is working or shortly after stopping, the refrigerant circulates inside the pipes, producing a gurgling water sound.

    2. The compressor surface temperature may reach 70°C to 80°C during operation.

    3. When the compressor starts or stops, the switch components may emit a slight clicking sound.

    4. During rainy and humid seasons, frost may form on the surface of the cabinet; wipe it off with a dry cloth.

    5. The inner lining of the freezer mouth is a stress relief area under ultra-low temperatures. Slight cracks may appear under alternating high and low temperatures, which is normal and does not affect use.

    Maintenance Instructions

    1. If abnormal phenomena or faults occur during use, please have a professional technician repair it (or under manufacturer guidance).

    2. Our factory provides free spare parts for domestic compressors (custom machines) within one year from the date of shipment, and free one-year warranty for imported compressors (standard machines).

    3. Warranty period: one year from delivery acceptance, excluding fragile glass parts (no returns or exchanges for custom machines). During warranty, logistics costs are paid by the shipping party (who ships pays), spare parts are provided free by the factory, with technical support. If compressor replacement is needed, the factory charges a service fee of 150 yuan, and refrigerant is provided free. For glass-covered low-temperature boxes, a quilt should be placed on the cover for insulation.

    Note: 1.   After unpacking, remove the base and keep ventilation.

    2. Please keep the wooden packaging for maintenance use; otherwise, the user bears the cost.

    3. It is strictly forbidden to operate continuously in environments above 35°C.

    Digital temperature controller instructions:

    Quickly press the “set” button three times consecutively to enter setting mode: first displays the lower limit setting (negative F). Use the up or down keys to select the lower limit value, then press set to lock it. Next, display the upper limit (positive F), use up or down keys to select the upper limit, then press set to lock it. Then display delay status Y—Y03 means a 3-minute delay before starting (must be set to Y03 to avoid compressor damage). Press set to lock delay. Then display JCC cooling mode (must be JCC), press set to lock. Then display C-6 temperature calibration range (factory adjusted), press set to lock. After waiting 16 seconds, all settings are saved and the actual internal temperature is displayed. (After setting, press set once more and wait 16 seconds before turning off, otherwise settings will not be saved).

    Setting example: (1) -25 degrees — lower limit negative F25, upper limit positive F22, delay Y03, cooling JCC, calibration C-6.   (Special note: The horizontal line between negative F and positive F flashes to indicate below zero; otherwise, positive L and negative L indicate above zero.) (2) -40 degrees — lower limit -40, upper limit -37, cooling, Y03, JCC, C-6.

    (3) -50 degrees — lower limit -50, upper limit -47, delay Y03, ... Wiring instructions: 1 neutral line, 2 live line. Cooling 1,3 output. 2,4 in series.

    Special note on temperature calibration C-6:

    If there is a discrepancy between the internal temperature and the meter display, quickly press the SET key three times: (1) negative F appears, (2) press SET again to show positive F, (3) press SET again to show Y03, (4) press SET again to show JCC, (5) press SET again to show C-6 for internal sensor calibration (range -6 to +6). After setting, press SET once more to confirm. Example: if the meter shows -24°C but the internal temperature is -25°C, change C-6 to C-1.

Company Profile

Hebei Yinfeng Experimental Instrument Co., Ltd. is a high-tech enterprise dedicated to the research and development, production, and sales of experimental instruments. The company is headquartered in Hebei Province, relying on the strong industrial foundation and technological innovation resources in the Beijing Tianjin Hebei region. It is committed to providing high-precision and high reliability testing equipment and solutions for material testing, engineering quality control, scientific research experiments and other fields.

Plant
Factory environment
Workshop
Workshop environment

Customized Delivery Process

We provide customers with full-process services ranging from pre-sale consultation, customized solution design, equipment installation and commissioning to after-sale technical support.

Online Communication

Provide Custom Drawings

Merchant Quotation

Sign A Contract

Processing And Production

Packaging And Distribution

Confirm Receipt Of Goods

Successful Transaction

  • Horizontal 160L Constant Temperature and Humidity Chamber
  • Horizontal 160L Constant Temperature and Humidity Chamber
  • Horizontal 160L Constant Temperature and Humidity Chamber
Horizontal 160L Constant Temperature and Humidity Chamber
Horizontal 160L Constant Temperature and Humidity Chamber
Horizontal 160L Constant Temperature and Humidity Chamber
+

Horizontal 160L Constant Temperature and Humidity Chamber

Temperature range: 0℃ to -40℃ Temperature control accuracy: ±2℃

If you need customized products,  Contact US !